Project Description
- Available with or without floating
bearing - Double seals can be applied at higher
pressure and rotating speed - Suitable for standardizations
- Rugged design to ensure long term
reliability and operating life - Seals are assembled in cartridge
construction for easy fitment - Over all connecting dimensions are
tailor made to customer’s specifications - The seal design is unique as it closes
due to the hydraulic product pressure
as well as overlaying barrier pressure
- Chemical industry
- Non-toxic media with single seal
- Pharmaceutical industry
- Toxic media with double seal
- Agitators
- Reactors
- FDA
DIN 28136 T3 (for glass-lined vessels)
DIN 28137 T2 (flange connection for glasslined vessels)
DIN 28159 (shaft end for glass-lined vessels)
- Options:
Cooling or heating flange
Leakage drain, flush or heating flange
Leakage drain or flush
Polymerization barrier, leakage drain or flush
- According to application and customer’s specifications
- Sizes: d3 = Upto 160 mm (Upto 6.500’’)
- Pressure: p1 = vacuum … 16 bar (232 PSI),
p3 = max. 18 bar (261 PSI) - Temperature: t1 = -40 °C … +200 (250) °C (-40 °F …
+392 (482) °F)
Speed = 0 … 5 m/s (0 … 16 ft/s)
- Single and Dual seal configuration
- Unbalanced design
- Independent of direction of rotation
- Cartridge construction
- Designed for top entry vessels
- Rotary unit with multiple springs
- Construction with Integrated bearing
also available - For glass-lined vessels, design
according to DIN 28138 T2